detergent with the type of materials listed above, always ask the supplier
a written confirmation of the compatibility. Should a chemical cleaner be
required, it is MANDATORY that all components are thoroughly rinsed
with water even if the instructions of the cleaner specify that it is a “no
rinse” cleaner. Failure to comply with above mentioned guidelines will
lead to a shortened life of the equipment to an indeterminable degree.
The repeated transportation of meat and fish waste can cause extensive
corrosion to the evaporator coils and evaporator section tubing over time
due to ammonia formation and can reduce the lifespan of the coils.
Appropriate additional measures should be taken to protect the coils
against the aggressive corrosion that can result from transportation of
such products.
LLooaadd CCoommppaarrttmmeenntt:: Inspect the interior and exterior of the truck for any
damage. Any damage to the walls or insulation should be repaired.
DDeeffrroosstt DDrraaiinnss:: Check the defrost drain hoses and fittings to ensure they are
not blocked.
DDoooorrss:: Verify doors and weather seals are in good condition and seal
hermetically.
SSiigghhtt ggllaassss:: Check that the refrigerant charge sight glass on the running
unit is totally full (the cargo compartment temperature must be
approximately 0ºC).
Weekly Post-Trip Checks
NNOOTTIICCEE
EEqquuiippmmeenntt DDaammaaggee!!
Do not use pressurised water.
1. Clean the outside cover of the unit. Use a damp cloth and neutral
detergents. Do not use harsh cleaning products or solvents.
2. Check for leaks.
3. Check for loose or missing hardware.
4. Check for physical damage to the unit.
Inspection and Service Schedules
To ensure that your Thermo King unit operates reliably and economically
over its full life, and to avoid limiting its warranty cover, the appropriate
inspection and service schedule must be followed. Inspection and Service
intervals are determined by the number of unit operating hours and by the
IInnssppeeccttiioonn aanndd SSeerrvviiccee IInntteerrvvaallss

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King Spectrum and is the answer not in the manual?

Thermo King Spectrum Specifications

General IconGeneral
BrandThermo King
ModelSpectrum
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals