Unit Description
26
Pharma
Single temperature units qualified for pharmaceutical
applications under Thermo King protocol. Please follow the
following recommendations:
• To maintain the best temperature management within the
load-space it is recommended to operate with the
following set-point temperatures in the following ranges.
• +20 °C Set-Point for temperature range +15 °C to +25
°C
• +5 °C Set-Point for temperature range +2 °C to +8 °C
• -25 °C Set-Point for temperature below -20 °C
• For optimum temperature management and air
distribution, the refrigeration unit’s continuous operation
mode must be used for all temperature ranges.
• Efficient loading practices and operating procedures have
to be followed to ensure optimum air circulation and
temperature management.
• Specific to 45 feet container with T-1200R ST Intermodal,
to ensure that good air circulation is maintained within the
load-space air chutes should be installed and maintained in
optimum condition.