Loading and Enroute Inspections
39
Enroute Inspections
Complete the following enroute inspection every four hours.
This will help minimize temperature related problems.
Inspection Procedure
1. Verify setpoint is correct.
2. Check the return air temperature reading. It should be
within the desired temperature range.
3. Initiate a manual defrost cycle after each enroute
inspection.
Inspection Troubleshooting
1. If a temperature reading is not within the desired
temperature range, refer to the troubleshooting table on the
following pages. Correct problem as required.
2. Repeat the Enroute Inspection every 30 minutes until the
compartment temperature is within the desired
temperature range. Stop the unit if the compartment
temperature is not within the desired temperature range on
two consecutive 30 minute inspections, especially if the
compartment temperature appears to be moving away
from the setpoint.
3. Immediately contact the nearest Thermo King Dealer or
your company office.
4. Take all necessary steps to protect and maintain proper
load temperature.

Other manuals for Thermo King T- series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King T- series and is the answer not in the manual?

Thermo King T- series Specifications

General IconGeneral
RefrigerantR-404A
Voltage12V/24V DC
DefrostElectric or Hot Gas
ModelT-series
Cooling CapacityVaries by model
Power SourceDiesel Engine or Electric
Temperature Range-29°C to 24°C
Control SystemMicroprocessor-based
Fuel Tank CapacityVaries by model
DimensionsVaries by model
WeightVaries by model

Related product manuals