30
Cooling Speed Set-ups
Air Flow
Fan
Control SW1
Switch
Settings
Clg.
Tonage
Cool Continous
Static
Pressure
in W.C. Watts Amps
0.2” 102 1.16
6-OFF
5-OFF
4-OFF
2 799 500
0.5” 165 1.83
0.2” 149 1.68
6-OFF
5-OFF
4-ON
2.5 1017 508
0.5” 238 2.60
0.2” 213 2.35
6-OFF
5-ON
4-OFF
3 1210 605
0.5” 306 3.27
0.2” 304 3.32
6-OFF
5-ON
4-ON
3.5 1404 702
0.5” 419 4.40
0.2” 462 4.83
Factory
SW1 Switch
Settings
6-ON
5-OFF
4-OFF
4 1622 799
0.5” 584 5.96
0.2” 813 8.18
6-ON
5-ON
4-OFF
5 2010 993
0.5” 1000 10.1
NOTE: All information is approximate. Results will vary by installation.
Figure 18-3: Cooling blower motor speed chart