Thermo Scientific Ion GeneStudio S5 Prime User Manual

Thermo Scientific Ion GeneStudio S5 Prime
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
For Research Use Only. Not for use in diagnostic procedures.
Ion 520
& Ion 530
ExT Kit – Chef
USER GUIDE
for use with:
Ion Chef
System
Ion S5
System
Ion S5
XL System
Ion GeneStudio
S5 System
Ion GeneStudio
S5 Plus System
Ion GeneStudio
S5 Prime System
Catalog Number A30670
Publication Number MAN0015805
Revision F.0

Table of Contents

Questions and Answers:

Thermo Scientific Ion GeneStudio S5 Prime Specifications

General IconGeneral
Output per RunUp to 50 Gb
Sample TypeDNA, RNA
ConnectivityEthernet, USB
Maximum Reads per RunUp to 80 million
Operating Temperature15°C to 30°C
Operating Humidity20% to 80% non-condensing
Platform TypeNext-Generation Sequencing
TechnologySemiconductor Sequencing
ApplicationsExome Sequencing, Targeted Sequencing, Transcriptome Sequencing
Chip TypesIon 530
Voltage Requirements100-240 V AC
WorkflowAutomated

Summary

Ion 520™ & Ion 530™ ExT Kit – Chef USER GUIDE

Chapter 1 Product information

Product description

Details the contents and purpose of the Ion 520™ & Ion 530™ ExT Kit – Chef for sequencing workflow.

Kit contents and storage

Details the components included in the kit and recommended storage conditions for optimal performance.

About the Ion Chef™ System

Provides an overview of the Ion Chef™ System's capabilities, automation, and integration with Torrent Suite™ Software.

Ion Chef™ Instrument components

Identifies and describes the major external and internal components of the Ion Chef™ Instrument.

Interior hardware and consumables

Illustrates and details the internal stations and consumables used in the Ion Chef™ Instrument for chip preparation.

About the Ion Chef™ System touchscreen interface

Explains the features and functions of the Ion Chef™ System's touchscreen interface for operation and maintenance.

Chapter 2 Before you begin

Precautions

Covers essential safety guidelines, including avoiding contamination and chip damage, and equipment protection.

Guidelines for using Ion Chef™ consumables and reagents

Provides best practices for handling and using Ion Chef™ consumables and reagents to ensure proper function.

Prepare the Ion Chef™ Instrument for use

Details the necessary steps to prepare the Ion Chef™ Instrument before loading consumables and starting a run.

Chapter 3 Create a Planned Run

Create a Planned Run

Provides step-by-step instructions for creating a Planned Run using the Torrent Suite™ Software.

Chapter 4 Start the Ion Chef™ run

Dilute the library

Explains how to dilute libraries to the optimal concentration for use in Ion Chef™ template runs.

Dilute the sample library

Details the procedure for diluting individual or combined sample libraries to the correct input concentration.

Prepare the consumables

Details the steps for preparing the necessary cartridges and consumables before loading them into the instrument.

Add the diluted libraries to the Ion Chef™ Library Sample Tube

Instructs on pipetting the diluted library into the correct tube for the Ion Chef™ Library Sample Tube.

Load the Ion Chef™ System

Guides the user through loading all required cartridges, tubes, and plates into the Ion Chef™ Instrument.

Load the tip racks and PCR Plate

Details the process of loading new tip cartridges and the PCR plate into the instrument.

Load the Reagents and Solutions cartridges

Instructs on how to load the Reagents and Solutions cartridges into the correct stations on the Ion Chef™ Instrument.

Load the Recovery Tubes and Enrichment Cartridge v2

Guides the user in loading Recovery Tubes and the Enrichment Cartridge v2 into the respective centrifuge and station.

Load the Chip-loading centrifuge

Provides detailed steps for assembling and loading the chip into the chip-loading centrifuge.

Start the Ion Chef™ run

Guides the user through initiating the Ion Chef™ run via the instrument touchscreen interface.

Unload the chip for sequencing

Details the procedure for safely removing the chip from the Ion Chef™ Instrument after the run is complete.

Chapter 5 Initialize the sequencer

Initialize the sequencer

Details the step-by-step procedure for initializing the sequencer, including cartridge and waste handling.

Chapter 6 Start the sequencing run

Start the sequencing run

Guides the user through initiating the sequencing run after chip loading and initialization are complete.

Chapter 7 Clean the Ion Chef™ System

Clean the Ion Chef™ Instrument

Provides instructions for cleaning the Ion Chef™ Instrument after each run to prevent contamination.

Start the cleaning

Provides instructions on how to initiate the automated cleaning cycle for the Ion Chef™ Instrument.

APPENDIX A Troubleshooting

APPENDIX C Safety