EasyManua.ls Logo

Thermo Ramsey Micro-Tech 3000 Series - COMM A and Printer Scroll Setup

Default Icon
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serial Communications 3104
REC XXXXX 3-5
- DISPLAY SCROLL 8 -
Date
> DD-MM-YYYY <
CHOICE ENTER
- DISPLAY SCROLL 9 -
Run display line 3
> No Display <
CHOICE ENTER
- MAIN MENU 5 -
Press MENU for more
COMM A PRINT
- COMM. A SCROLL 1 -
Baud rate port #1
> 2400 <
CHOICE ENTER
Then date can be set to show month or day first, in three possible configurations:
Password: Service
If USA: Default: MM-DD-YYYY
If other language: Default: DD-MM-YYYY
Selections: DD-MM-YYYY, MM-DD-YYYY, YYYY-MM-DD
3. When a COMM board is installed, date and time can be displayed line three
(3) in the RUN screen if selected using DISPLAY SCROLL 9.
Password: Operator
Default: NO DISPLAY
Selections: NO DISPLAY, LOAD, SPEED, DATE/TIME
3.4.2 COMM A and Print Scroll Set-Up
Main Menu 5 is dedicated to the serial line. COMM A is used to set up the serial
line of the COMM A , regardless if the serial line is connected to a computer or
a PLC or for printing. The PRINT scroll is used for setting up the printer, and it only
appears if the COMM A is set for printer.
1. Line Setting and Protocol Definition
Two COMM line can be installed and programmed, typically one for the printer and one for the
supervisor.
The following screens define the communication parameters for the first and the second channel.
Password
: Service
Default: 9600
Selections: 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200