Thytronic NA11 - Page 160

Thytronic NA11
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
160
160
NA11 - Manual - 02 - 2009
APPENDIX
Description Parameter Unit Setting range
IN29 matching
Reset LEDs | Set profi le | Fault trigger | Block2
IPh/IE | Block2 IPh | Block2 IE | Block1 | TCS1 | TCS2
| Trip ProtExt | Reset counters | Reset CB Monitor |
52a | 52b | Open CB | Close CB | Remote trip | Reset
on demand measures | 79 Enable | 79 Block | None
Binary input IN30
IN30
Logic
Active-ON | Active-OFF
IN30 tON
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN30 tOFF
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN30 matching
Reset LEDs | Set profi le | Fault trigger | Block2
IPh/IE | Block2 IPh | Block2 IE | Block1 | TCS1 | TCS2
| Trip ProtExt | Reset counters | Reset CB Monitor |
52a | 52b | Open CB | Close CB | Remote trip | Reset
on demand measures | 79 Enable | 79 Block | None
Binary input IN31
IN31
Logic
Active-ON | Active-OFF
IN31 tON
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN31 tOFF
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN31 matching
Reset LEDs | Set profi le | Fault trigger | Block2
IPh/IE | Block2 IPh | Block2 IE | Block1 | TCS1 | TCS2
| Trip ProtExt | Reset counters | Reset CB Monitor |
52a | 52b | Open CB | Close CB | Remote trip | Reset
on demand measures | 79 Enable | 79 Block | None
Binary input IN32
IN32
Logic
Active-ON | Active-OFF
IN32 tON
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN32 tOFF
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN32 matching
Reset LEDs | Set profi le | Fault trigger | Block2
IPh/IE | Block2 IPh | Block2 IE | Block1 | TCS1 | TCS2
| Trip ProtExt | Reset counters | Reset CB Monitor |
52a | 52b | Open CB | Close CB | Remote trip | Reset
on demand measures | 79 Enable | 79 Block | None
Binary input IN33
IN33
Logic
Active-ON | Active-OFF
IN33 tON
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN33 tOFF
Value
s
0.00 ... 9.99 step = 0.01
10.0 ... 100.0 step = 0.1
IN33 matching
Reset LEDs | Set profi le | Fault trigger | Block2
IPh/IE | Block2 IPh | Block2 IE | Block1 | TCS1 | TCS2
| Trip ProtExt | Reset counters | Reset CB Monitor |
52a | 52b | Open CB | Close CB | Remote trip | Reset
on demand measures | 79 Enable | 79 Block | None
Binary input IN34