1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
Before installation or maintenance, ensure the mains supply to the
programmable room thermostat is switched off and the circuit supply
fuses are removed or the circuit breaker turned off.
It is recommended that a qualified electrician is consulted or used for
the installation of this programmable room thermostat and install in
accordance with the current IEE wiring and Building Regulations.
Check that the total load on the circuit including when this programmable
room thermostat is fitted does not exceed the rating of the circuit cable,
fuse or circuit breaker.
To clean use a clean dry cloth only. Do not use any liquid cleaners.
3. Technical Specifications
230V AC 50 Hz
This thermostat is of Class ll Construction and must not be earthed
Switch Rating: 3(1)A
Switch Type: Single pole, voltage free
changeover contacts
Connection Type: 2 wire
Installation Type: Surface mount with wall plate
Micro Disconnection: Type 1.B control action
Operating Temperature Range: 0°C to +40°C
Set Temperature Range: 10°C to 35°C
Temperature Swing Adjuster: +/- 0.5°C or 1.0°C set by DIP switch
Optimum Start Time
(OST) Adjustment: ON or OFF set by DIP switch
Frost Protection Mode: 5°C, Fixed
Sleep Mode: Suspends all output, turns off display