Version D January 2021
2.3.3 Two limit switches to cut the current and an additional limit switch for
signal output
The actuator is equipped with two limit switches to cut the current of the motor when the actuator moves to
the end of each stroke, and an additional limit switch sends out the signal at specific stroke positions.
*Please refer to section 2.3.2 for cut current module.
Connect to Vm+ to extend the actuator.
Connect to Vm- to retract the actuator.
24V version: Input voltage 18~32 V DC.
12V version: Input voltage 9~16 V DC.
Connect to Vm- to extend the actuator.
Connect to Vm+ to retract the actuator.
Connect to up limit switch normal closed
pin (N.C.)
The signal is potential free and independent
from the motor power circuit.
The signal is short circuit when the actuator
moves to the position where the additional
limit switch is triggered.
The additional limit switch, installed in
position by customer request, is factory
preset and non-adjustable.
Connect the additional limit switch signal
with max 32V, <1A.
Connect to low limit switch normal closed
pin (N.C.)