Performance Series 450e 13
Remedy in case of faults
Type of malfunction
D. Coating material exits at the top
oftheuidsection
E. Increased pulsation at the spray
gun
F. Poor spray pattern
G. Unitlosespower
Possible cause
1. Upperpackingisworn.
2. Piston is worn.
1. Incorrect high-pressure hose type.
2. Tip worn or too large.
3. Pressure too high.
1. Tip is too large for the coating
material which is to be sprayed.
2. Pressure setting incorrect.
3. Volumetoolow.
4. Coating material viscosity too high.
1. Pressure setting too low.
Measures for eliminating the malfunction
1. Remove and replace packing.
2. Remove and replace piston.
1. Only use TITAN original-high-pressure hoses in order
to ensure functionality, safety and durability.
2. Replace tip.
3. Turn pressure control knob to a lower number.
1. Replace tip.
2. Turn pressure control knob until a satisfactory
spraying pattern is achieved.
3. Cleanorreplacealllters.
4. Thinoutaccordingtothemanufacturer’sinstructions.
1. Turn pressure control knob clockwise to increase.