Table of Contents

Questions and Answers

  • J
    juanjohnsonSep 12, 2025
    Why does the ACG warning system come on in my TOHATSU BFT 80A?
    • E
      Emma GarciaSep 12, 2025
      If the ACG warning system comes on in your TOHATSU Outboard Motor, it indicates that the battery voltage is either too high or too low. Check the battery.
  • J
    John SpenceSep 15, 2025
    What to do if the MIL and warning buzzer does not operate on my TOHATSU BFT 80A Outboard Motor?
    • D
      Daniel HobbsSep 15, 2025
      If the MIL and warning buzzer of your TOHATSU Outboard Motor do not operate, the possible solutions include replacing the blown fuse and checking for a short in the main wire harness or incorrect load by referring to the "FUSE LOAD CHART". Other solutions are replacing the ECM or the PGM-FI/main relay with a new one and rechecking. Also, repair any opens in the wire harness between the ECM and engine ground, between the battery and combination switch, or between the ECM and PGM-FI/main relay. A faulty combination switch may also be the cause.

TOHATSU BFT 80A Specifications

General IconGeneral
Power Output80 hp
Cylinder4
StartingElectric
Gear Ratio2.33:1
SteeringRemote
Displacement1496 cc
Bore x Stroke73 mm x 89.4 mm
Full Throttle RPM Range5, 000 - 6, 000
Shaft Length20" (L), 25" (XL)