31/35
9.2. Data processing function
It processes the measured data to calculate the data quantity, maximum/ minimum/
average torque of the selected data range
i. Set the counter number to the upper end that you need using ▲▼ keys, then press
“MD” key to the next
ii. Set the number on right display to the lower end that you need using ▲▼ keys then
press “MD” key to the next
Example 1) To process data 001 to 200
Set counter to 200 and press “MD” key. Confirm STT shows 1 and press “MD” to the next
Example 2) To process data 101 to 200
Set counter to 200 and press “MD” key. Set STT number to 101 and press “MD” to the next
NOTE: Only peak hold and saved data will be processed
iii. The right display shows the number of data to process. Press “MD” key to proceed or
press “C” key to go back to measurement mode
iv. The display shows maximum value of the selected data range. Press “MD” key to
proceed or press “C” key to go back to measurement mode