9/35
4.9. Auto power off
When it is left without any key operation of tightening operation for a set time
(default setting is 3 minutes) or unloading condition (loading torque is less than
7.5% of the max. torque range of the model), the power will automatically turn off.
If you prefer not to use Auto power off, set it to OFF.
At “LoBATT” alarm condition, power will turn off in 1 minute regardless of the above
condition
4.10. Residual battery indicator
Residual battery amount is indicated on the display as follows:
Full
Half remaining
Time to charge battery
No battery available. Recharge immediately.
No key operation works, and it automatically turns off in 1 minute.
Each settings and data remain unchanged even after “LoBATT”
condition.
4.11. Over-torque alarm
When it exceeds 105% of the maximum measurable torque, the value on the
display and “- - - -“ blinks alternatively and the buzzer does on.
4.12. Over-torque alarm/ Peak torque hold starting value
※ Values in ( ) is the minimum setting value of trigger torque
※ Accuracy for the trigger torque set below the minimum torque value can’t be guaranteed
(N.m case)
Over-torque alarm Peak hold starting torque
Min. Max.
(105% of Max.
capacity torque)
(7.5% of Max.
capacity torque)
CEM10N3X8D-G-BTA (0.50)2.00 10.00 0.01 10.50 0.75 0.75
CEM20N3X10D-G-BTA (1.00)4.00 20.00 0.02 21.00 1.50 1.50
CEM50N3X12D-G-BTA (2.50)10.00 50.00 0.05 52.50 3.75 3.75
CEN100N3X15D-G-BTA (5.0)20.0 100.0 0.1 105.0 7.5 7.5
CEM200N3X19D-G-BTA (10.0)40.0 200.0 0.2 210.0 15.0 15.0
CEM360N3X22D-G-BTA (18.0)72.0 360.0 0.4 378.0 27.0 27.0
CEM500N3X22D-G-BTA (25.0)100.0 500.0 0.5 525.0 37.5 37.5
CEM850N3X32D-G-BTA (43)170 850 1 893 64 64
Model
Torque range
Auto zero range
(7.5% of Max.
capacity torque)
1 digit