10. Error messages
11. Common specifications
Error message Indication Solution
Err0
Error in angle
speed detection
Turn off the power once. Keep the body still (no movement)
and turn on the power again.
-If Err0 disappears, then it operates normally.
-If Err0 remains on the display, contact TOHNICHI
or your nearest distributo to ask for repair.
Err1
Upper arrow key is
continuously pressed
Err2
Down arrow key is
continuously pressed
Err3
"MEM" key is
continuously pressed
Err4
"C" key is
continuously pressed
Err5
"MD" key is
continuously pressed
Err8 Memory abnormality
It needs to be reapired. Please contact TOHNICHI
or your nearest distributo to ask for repair.
Err9
Torque sensor
abnormality
Press "C" key without load.
-If Err9 disappears, then it operates normally.
-If Err9 remains on the display, contact TOHNICHI
or your nearest distributo to ask for repair.
Turn off the power once and turn it on without touching any other keys.
-If error message disappears, then it operates normally.
-If error message remains on the display, contact TOHNICHI
or your nearest distributo to ask for repair.
Torque accuracy ±1%
Angle accuracy ±2°
1digit
rotating 90 degrees at speed of 30
180°/sec
Display
7 segments LED 4 digits
14 segments LCD 6 digits
7 segments LCD 4digits
OK/ NG judgment LED Blue
Red
Bluetooth® power LED Red
Bluetooth®connection status LED Blue
Battery level indicator 4 steps
Data quantity
999 readings
(Tightening torque, final angle, judgment result and time)
Basic functions
Peak hold
Measured data transmission
Auto reset (Torque and angle)
Tightening completion alarm
OK/ NG judgment
Auto zero
Auto power off
Over torque alarm
Clock
Communication
Bluetooth® V3.0 (Profile: SPP)
RS232C compliant (2400-19200 bps)
USB connector corresponding serial output
Power Nickel hydrogen battery (BP-5)
Continuous operation Aprox. 8 hours
Charging time Aprox. 3.5 hours
Communication
mode change
Key operation
Operating temperature 0
40 degrees Celsius (no condensation)

Related product manuals