EasyManuals Logo

Tohnichi R-CM User Manual

Tohnichi R-CM
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
  10
Modular Conversoin Receiver Model: R-CM
Terminals for Count Checker function
[INPUT TERMINAL]
● END Input terminal: IN2
Input terminal for work end signal.
By connecting it to COM terminal via 0.1 seconds or more of contact relay signal generated by a push
button switch, PLC etc., pass/fail judgment is performed based on the remaining count at that time.
● RESET Input terminal: IN2
Input terminal for work end signal.
By connecting it to COM terminal via 0.1 seconds or more of contact relay signal generated by a push
button switch, PLC etc., initializes the count display to the tightening number setting, and the pass/fail
judgment lamp, outout it will be OFF.
[OUTPUT TERMINAL]
● OK Output terminal: OUT1
Outouts a relay signal as OK result from this terminal when the count number was "0" and END input
signal is inputted or auto judgment timer is expired.
● NG Output terminal: OUT2
Outputs a relay signal as NG result from this terminal when count over Is set at NG and count exceed
set count, an END signal has been inputted at the time count remaining or auto judgment timer
expired.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tohnichi R-CM and is the answer not in the manual?

Tohnichi R-CM Specifications

General IconGeneral
BrandTohnichi
ModelR-CM
CategoryReceiver
LanguageEnglish