OPERATION & MAINTENANCE
4.4
Note: Vapor venting from the bottom port at the rear of the compression cylinder is
normal. Do not plug or restrict this port by any means.
High capacity machines do not have this port.
9. To end dry ice production, push the STOP button. The pelletizer will complete
the current cycle before stopping.
Note: To stop the pelletizer immediately press the EMERGENCY STOP button.
The pelletizer will not complete the current cycle and CO
2
may be left in the
compression cylinder. Any CO
2
left in the compression cylinder will sublime
and vent to atmosphere through the extrusion die. When the pelletizer is re-
started, the machine will go through an automatic clean-out cycle before begin-
ning an injection cycle, so no user action is required when restarting.