17
How to set slopes
1 Turn the instrument on by pressing the Power control pad. Auto-leveling will start.
2 Press the X/Y Axis Selection control pad once after auto-leveling is complete (see page
10). The X axis lamp will ash. To change to Y axis, press the X/Y pad once again. Press-
ing the X/Y pad toggles between X and Y axis selection.
3 Select Laser Pointing mode to stop beam rotation and manu-
ally align the beam over the X axis (see illustration on previ-
ous page).
4 To move the laser beam up or down, press and hold the right
or left Alignment Control pad. The Manual mode lamp will
illuminate. The ashing X axis lamp will change to solid after
several seconds indicating slope has been entered in the X
axis.
5 To set a compound slope, repeat steps 2 to 4 for the Y axis.
To cancel slope settings
Press the Manual Mode pad. The instrument returns to auto-
leveling mode.
Setting slope in Y axis
Raise or lower the laser beam by pressing the right or left Alignment Control pad.
Sample; Laser pointing mode
Move the beam up or down by
pressing the right or left align-
ment keys