PROBLEM CAUSE-SOLUTION
Sporadic Tool Action: • Air in the hydraulic system. Bleed the hydraulic circuit.
• Check reservoir oil level.
Motor Will Not Start: • Too much water in air line, froze motor
• Not enough air pressure
• Have motor checked for proper operation.
• Check air adjustment knob on FRL
.
Noisy Operation: • Air in system.
• Be sure the oil reservoir is lled to normal level.
• Check all points where air might leak into system.
• Clogged or blocked intake screen.
Pump Oil is Over Heating: • Inspect for high pressure leakage at the pump (leaking at
plug or relief valve).
• Oil level is low. Fill reservoir to normal level, or retrot the
pump with larger reservoir or heat exchanger.
Pump Runs But Will
Not Build Pressure: • Pump is not primed. Run pump a few minutes tipping from
side to side.
• Inspect to make sure that external adjustable relief valve is
set properly.
• Defective control valve, take to nearest TorcUP Authorized
Service Center for repair.
• Check to make sure the intake screen is not clogged. Clean
if needed.
• Check oil reservoir is low. Fill as needed.
• Oil viscosity is too high. Replace with TorcUP oil.
• Supplying air line too small
• Not enough air pressure
TROUBLE SHOOTING