PROBLEM CAUSE-SOLUTION
Sporadic Tool Action: Air in the hydraulic system. Bleed the hydraulic circuit.
Check reservoir oil level.
Motor Will Not Start: Too much water in air line, froze motor
Not enough air pressure
Have motor checked for proper operation.
Check air adjustment knob on FRL
.
Noisy Operation: Air in system.
Be sure the oil reservoir is lled to normal level.
Check all points where air might leak into system.
Clogged or blocked intake screen.
Pump Oil is Over Heating: Inspect for high pressure leakage at the pump (leaking at
plug or relief valve).
Oil level is low. Fill reservoir to normal level, or retrot the
pump with larger reservoir or heat exchanger.
Pump Runs But Will
Not Build Pressure: Pump is not primed. Run pump a few minutes tipping from
side to side.
Inspect to make sure that external adjustable relief valve is
set properly.
Defective control valve, take to nearest TorcUP Authorized
Service Center for repair.
Check to make sure the intake screen is not clogged. Clean
if needed.
Check oil reservoir is low. Fill as needed.
Oil viscosity is too high. Replace with TorcUP oil.
Supplying air line too small
Not enough air pressure
TROUBLE SHOOTING