25
DAILY MAINTENANCE
DRAINING AND CLEANING THE RECOVERY TANK
1. Hold the exhaust hose placed on the front part of the machine after having taken it off from its
fixing support.
2. Take off the plug from the exhaust hose acting upon its lever and empty the recovery tank
into appropriate containers, in compliance with the respective rules what the liquid disposal
concerns.
3. Clean the inside of the tank using a water jet.
DRAINING AND CLEANING THE SOLUTION TANK
1. Hold the exhaust hose (1) placed on the right side of the machine after having removed it from
its fixing support.
2. Open the solution valve (2) of the exhaust hose located on it and empty the solution tank
into appropriate containers, in compliance with the respective rules what the liquid disposal
concerns.
3. Rinse the tank with a water jet.
4. Once it has been completely emptied, close the solution valve (2).
CLEANING THE SUCTION FILTER
1. Open the cover (1) and unscrew the knob (2) to release the filter protection (3).
2. Rotate the filter protection clockwise to release it.
3. Take off the filter and its protection.
4. Clean with a water jet especially the bottom part and the sides of the filter.
5. Do the cleaning procedure precisely.
MAINTENANCE