Figure 73
1. Test port B
T est P or t C ( Figure 74 ), located on the left side of
the mac hine , is used to measure the left cutting
unit pressure .
Figure 74
1. Test port C
T est P or t D ( Figure 75 ), located on the right side
of the mac hine , is used to measure the right cutting
unit pressure .
Figure 75
1. Test port D
T est P or t E ( Figure 76 ), located under the radiator ,
is used to measure the four -wheel dri v e pressure
in rev erse .
Figure 76
1. Test port E
T est P or t F ( Figure 77 ), located under the seat, is
used to measure the lift circuit pressure .
T est P or t G ( Figure 77 ), located under the seat, is
used to measure the c harg e circuit pressure .
Figure 77
1. Test port F
2. Test port G
T est P or t H ( Figure 78 ) is used to measure the
front cutting unit circuit pressure .
T est P or t J ( Figure 78 ) is used to measure the
steering circuit pressure .