EasyManua.ls Logo

Toro 30607 - Page 43

Toro 30607
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
g213424
Figure51
Iftheregenerationprocessisnot
allowedbytheenginecomputer,the
“DPFRegenNotAllowed”message
displaysintheInfoCenter(Figure52).
Presstheleftbuttontoexittothehome
screen
Important:Ifyoudidnotmeetallthe
requirementsforregenerationorif
lessthan50hourshavepassedsince
thelastregeneration,the“DPFRegen
NotAllowed”messageappears.
g212410
Figure52
8.Whiletheregenerationisrunning,theInfoCenter
returnstothehomescreenandshowsthe
followingicons:
Theengineiscold—wait.
Theengineiswarm—wait.
Theenginehot—regenerationinprogress
(percentcomplete).
9.Theparkedregenerationiscompletewhenthe
“RegenComplete”messagedisplaysinthe
InfoCenter.Presstheleftbuttontoexittothe
homescreen(Figure53).
g212404
Figure53
RecoveryRegeneration
Ifyouignoretherequestforaparkedregeneration
(displayedintheInfoCenter)andcontinueto
operatethemachine,acriticalamountofsoot
buildsupintheDPF.
Ifarecoveryregenerationisneeded,the
InfoCenterdisplaysenginewarningSPN3719,
FMI16(Figure54)andtheenginecomputer
deratesenginepowerto85%.
g213867
Figure54
Important:Ifyoudonotcompletearecovery
regenerationwithin15minutes,theengine
computerderatesenginepowerto50%.
43

Table of Contents

Other manuals for Toro 30607

Related product manuals