Loading...
Important:Useonlythehydraulicuids
specied.Otheruidscouldcausesystem
damage.
12.Starttheengineanddrivethesprayertollthe
hydraulicsystem.Rechecktheoillevelandreplenish
it,ifrequired.
ReplacingtheHydraulicFilter
ServiceInterval:Aftertherst8hours
Every800hours/Yearly(whichever
comesrst)
UsetheTororeplacementlter(PartNo.54-0110).
Important:Useofanyotherltermayvoidthe
warrantyonsomecomponents.
1.Positionthesprayeronalevelsurface,settheparking
brake,stopthepump,stoptheengine,andremove
theignitionkey.
2.Cleantheareaaroundtheltermountingarea.
3.Placeadrainpanunderthelter.
4.Removethelter(
Figure68).
Figure68
1.Hydrauliclter2.Gasket
5.Lubricatethenewltergasket.
6.Ensurethattheltermountingareaisclean.
7.Screwthelteronuntilthegasketcontactsthe
mountingplate,thentightenthelterone-halfturn.
8.Starttheengineandletitrunforabouttwominutes
topurgeairfromthesystem.Stoptheengineand
checkthehydraulicoillevelandforleaks.
SpraySystem
Maintenance
WARNING
Chemical substances used in the spray system may
be hazardous and to xic to y ou, bystander s, animals,
plants, soils or other pr oper ty .
Carefullyreadandfollowthechemical
warninglabelsandMaterialSafetyData
Sheets(MSDS)forallchemicalsusedand
protectyourselfaccordingtothechemical
manufacturer’srecommendations.Forexample,
useappropriatePersonalProtectiveEquipment
(PPE)includingfaceandeyeprotection,gloves,
orotherequipmenttoguardagainstpersonal
contactwiththechemical.
Keepinmindthattheremaybemorethanone
chemicalusedandinformationoneachshould
beassessed.
R efuse to operate or w or k on the spray er if this
inf or mation is not a v aila ble!
Beforeworkingonaspraysystemmakesurethe
systemhasbeentriplerinsedandneutralized
accordingtotherecommendationsofthe
chemicalmanufacturer(s).
Verifythereisanadequatesupplyofcleanwater
andsoapnearby,andimmediatelywashoffany
chemicalsthatcontactyou.
InspectingtheHoses
ServiceInterval:Every200hours—Inspectallhoses
andconnectionsfordamageand
properattachment.
Examineeachhoseinthespraysystemforcracks,
leaksorotherdamage.Atthesametime,inspectthe
connectionsandttingsforsimilardamage.Replaceany
hosesandttingsifdamaged.
PumpMaintenance
InspectingthePump
ServiceInterval:Every400hours/Yearly(whichever
comesrst)—Inspectthepump
diaphragmandreplaceifnecessary.
(seeanAuthorizedToroService
Distributor)
Every400hours/Yearly(whichever
comesrst)—Inspectthepressure
dampenerbladderandreplaceif
55