EasyManua.ls Logo

Toro 74909TE - Sound Pressure; Sound Power; Vibration Level

Toro 74909TE
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SlopeOperation
Donotmowslopesgreaterthan15degrees.
Donotmowneardrop-offs,ditches,steepbanks,or
water.Wheelsdroppingoveredgescancauserollovers,
whichmayresultinseriousinjury,death,ordrowning.
Donotmowslopeswhengrassiswet.Slippery
conditionsreducetractionandcouldcauseslidinganda
lossofcontrol.
Donotmakesuddenturnsorrapidspeedchanges.
Useawalkbehindmowerand/orahandtrimmernear
drop-offs,ditches,steepbanks,orwater.
Reducespeedanduseextremecautiononslopes.
Removeormarkobstaclessuchasrocks,treelimbs,etc.
fromthemowingarea.Tallgrasscanhideobstacles.
Watchforditches,holes,rocks,dips,andrisesthatchange
theoperatingangle,asroughterraincouldoverturnthe
machine.
Avoidsuddenstartswhenmowinguphill,becausethe
mowermaytipbackward.
Beawarethatlossoftractionmayoccurgoingdownhill.
Weighttransfertothefrontwheelsmaycausedrive
wheelstoslipandcauselossofbrakingandsteering.
Alwaysavoidsuddenstartingorstoppingonaslope.
Iftireslosetraction,disengagethebladesandproceed
slowlyofftheslope.
Followthemanufacturer'srecommendationsforwheel
weightsorcounterweightstoimprovestability.
Useextremecarewithgrasscatchersorotherattachments.
Thesecanchangethestabilityofthemachineandcausea
lossofcontrol.
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof92
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Thesoundpressurelevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Thesoundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
VibrationLevel
Hand-Arm
Measuredvibrationlevelforrighthand=2.4m/s
2
Measuredvibrationlevelforlefthand=1.6m/s
2
UncertaintyValue(K)=1.2m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBody
Measuredvibrationlevel=0.45m/s
2
UncertaintyValue(K)=0.22m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.