Greensmaster 3250−D
Page 5 − 13
Electrical System (Rev. C)
Leak Detector (Optional)
Operation
The leak detector system is designed to assist in the ear-
ly detection of hydraulic oil system leaks. If the oil level
in the main tank is lowered by 4 to 5 ounces, the level
switch in the leak detection tank will close. After a 1 se-
cond delay, the alarm will sound alerting the operator.
Expansion of oil from the normal heating of the hydraulic
oil during machine operation will cause oil to transfer into
the leak detection tank. The oil is allowed to return to the
main tank when the ignition switch is turned off (see Fig.
12, 13, and 14).
Figure 12
BEFORE START (oil cold)
ÉÉÉ
ÉÉÉ
ÉÉÉ
ÉÉ
ÉÉ
ÉÉ
ÉÉ
ÉÉ
FILLER CAP
FLUID LEVEL
COLD
SOLENOID
RETURN
VALVE
OPEN
SIGHT
WINDOW
NO SOUND
FLOAT RAISED
SWITCH OPEN
Figure 13
NORMAL OPERATION (oil warm)
ÉÉ
ÉÉ
ÉÉ
ÉÉ
ÉÉ
ÉÉÉ
ÉÉÉ
ÉÉÉ
ÉÉ
ÉÉ
FLOAT RAISED
SWITCH OPEN
NO SOUND
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
CLOSED
Figure 14
LEAK ALERT!
ÉÉ
ÉÉ
ÉÉ
ÉÉÉ
ÉÉÉ
ÉÉ
FLOAT DOWN, SWITCH CLOSED
(FLUID LEVEL DOWN 4 TO 5 OUNCES)
FLUID LEVEL
WARM
SOLENOID
RETURN
VALVE
CLOSED
WARNING
BUZZER
SOUNDS
Electrical
System

Table of Contents