Glow-Plug-IndicatorLight(Orange
Light)
Theglow-plug-indicatorlight(Figure7)turnsonwhen
youturntheignitionswitchtotheONposition.It
remainsonfor6seconds.Whenthelightturnsoff,
youcanstarttheengine.
Charge-IndicatorLight
Thecharge-indicatorlightilluminateswhenthe
charging-systemcircuitmalfunctions(Figure7).
Oil-PressureWarningLight
Theoil-pressurewarninglightglowsiftheengine-oil
pressuredropsbelowasafelevel(Figure7).Ifthe
oilpressureislow,shutofftheengineanddetermine
thecause.Repairtheengine-oilsystembeforeyou
starttheengineagain.
SteeringSelectorSwitch
4-WheelDriveMachinesOnly
Pressthesteeringselectorswitchtotherearto
engage4-wheelsteeringandforwardtoreturnto
2-wheelsteering(Figure7).
DiagnosticLight
4-WheelDriveMachinesOnly
Thediagnosticlightilluminateswhenthesystem
detectsafault(Figure7).
UnderstandingtheDiagnostic
Light
4-WheelDriveMachinesOnly
Themachinecomeswithadiagnosticlightthat
indicatesiftheelectroniccontrollersensesan
electronicmalfunction.Thediagnosticlightislocated
onthecontrolpanel(Figure9).Whentheelectronic
controllerisfunctioningcorrectlyandthekeyswitch
ismovedtotheONposition,thecontrollerdiagnostic
lightturnsonfor3secondsandturnofftoindicatethat
thelightisworkingproperly.Iftheengineshutsoff,the
lightturnsonsteadyuntilyouchangethekeyposition.
Thelightblinksifthecontrollerdetectsamalfunction
intheelectricalsystem.Thelightstopsblinkingand
automaticallyresetswhenyouturnthekeyswitchto
theOFFpositionwhenthefaulthasbeenresolved.
g014333
Figure9
1.Diagnosticlight
Whenthecontrollerdiagnosticlightblinks,1of
thefollowingproblemshasbeendetectedbythe
controller:
Anoutputhasbeenshorted.
Anoutputhasanopencircuit.
Usethediagnosticacedisplaytodeterminewhich
outputismalfunctioning.
Ifthediagnosticlightdoesnotcomeonwhenthekey
switchisintheONposition,thisindicatesthatthe
electroniccontrollerisnotoperating.Possiblecauses
areasfollows:
Thelightisburnedout.
Thefusesareblown.
Theelectroniccontrollerisnotfunctioning
correctly.
Checktheelectricalconnections,inputfuses,and
diagnosticlightbulbtodeterminethemalfunction.
Ensurethattheloop-backconnectorissecuredtothe
wire-harnessconnector.
16

Table of Contents