EasyManua.ls Logo

Toro Groundsmaster 7210 Series - Soot-Load Table; Passive DPF Regeneration

Toro Groundsmaster 7210 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
presstherightbuttontoselecttheTechnicianentry
(Figure34).
g227348
Figure34
UsetheDPFoperationtabletounderstandthe
currentstateofDPFoperation(Figure35).
g227360
Figure35
.
DPFOperationTable
State
Description
NormalTheDPFisinnormal-operating
mode—passiveregeneration.
AssistRegen
Theenginecomputerisperformingan
assistregeneration.
Theregeninhibit
settingissettoON.
ResetStby
Theengine
computeristrying
torunareset
regeneration,but
1ofthefollowing
conditionsprevents
regeneration:
Theexhaust
temperature
istoolowfor
regeneration.
DPFOperationTable(cont'd.)
State
Description
ResetRegenTheenginecomputerisrunningareset
regeneration.
ParkedStby
Theenginecomputerisrequestingthat
yourunaparkedregeneration.
ParkedRegenYouinitiatedaparkedregeneration
requestandtheenginecomputeris
processingtheregeneration.
Recov.Stby
Theenginecomputerisrequestingthat
yourunarecoveryregeneration.
Recov.RegenYouinitiatedarecoveryregeneration
requestandtheenginecomputeris
processingtheregeneration.
Viewthesootloadwhichismeasuredasthe
percentageofsootintheDPF(Figure36);referto
thesoot-loadtable.
Note:Thesootloadvaluevariesasthemachine
isoperatedandDPFregenerationoccurs.
g227359
Figure36
Soot-LoadTable
ImportantSootLoadValuesRegenerationState
0%to5%
Minimumsootloadrange
78%Theenginecomputerperforms
anassistregeneration.
100%
Theenginecomputer
automaticallyrequestsa
parkedregeneration.
122%
Theenginecomputer
automaticallyrequestsa
recoveryregeneration.
PassiveDPFRegeneration
Passiveregenerationoccursaspartofnormal
engineoperation.
Whileoperatingthemachine,runtheengineat
full-enginespeedandhighloadwhenpossibleto
promoteDPFregeneration.
31