FuseBlockandFuses
Thefuseblockhousesthefusesthatprotecttheelectricalsystemfromelectrical
surges.
Note:AlwaysuseTorofuseswhenreplacingadamagedorblownfuse.
FuseBlockandFusesTest
1.Visuallyinspectthefuses.Afailedfusecanbeidentiedbyabrokenor
meltedelementinsidethefusecoveroradamagedspade.
g336414
Figure107
2.Usingadigitalmulti-metersettotheOHMorContinuitysetting,checkthe
continuitybetweenthefuseblades.IfthefuseisOPEN(nocontinuity),
replacethefuseandtestthecircuit.
Key/IgnitionSwitch
Theignitionswitchmakestheproperconnectionsforthestarter,safety
circuits,andaccessories.Detentsinsidetheswitchcontrolthethreeswitch
positions:OFF ,RUN,andSTART.TheSTARTpositionisspringloadedsothatit
automaticallyreturnstotheRUNpositionwhenreleased.
IgnitionSwitchWiringConnections
•B-BatteryVoltageIn
•S-StartingCircuit
•I-PTOSwitch
•A-OperatorPresenceSwitch,SafetyInterlockSwitches
•R-Regulator,ChargingCircuit
ElectricalSystem:ServiceandRepairs
Page8–4
TITAN®MaxServiceManual
3442-428RevA