NeutralSwitch-LeftandRight
Theneutralswitchisasinglepoleplungertypeswitch(normallyopen)with
twoterminals.Whentheplungerisdepressed,thecircuitclosesandthereis
continuitybetweentheterminals.
Motioncontrolleversinneutralposition(OUT),theswitchwillhavecontinuity
(closed).
Motioncontrolleversintheoperatingposition(IN),theswitchwillNOThave
continuity(open).
g336403
Figure111
ParkingBrakeSwitch
Theparkingbrakeswitchisasinglepoleplungertypeswitch(normallyopen)
withtwoterminals.Whentheplungerisdepressed(parkingbrakeON),the
circuitclosesandthereiscontinuitybetweentheterminals.Thisallowsbattery
voltagetoowtotherestofthesafetyinterlocksystem.
ParkingbrakeON,theswitchshouldhavecontinuity(closed).
ParkingbrakeOFF,theswitchshouldNOThavecontinuity(open).
g344832
Figure112
TITAN®MaxServiceManual
Page8–7
ElectricalSystem:ServiceandRepairs
3442-428RevA