g336408
Figure115
Note:TheenginewillnotcrankoverwhenthePTOswitchisintheONposition.
AllswitchesaresuppliedinparallelandfeedintotheHourMeter.
PTOSwitchTest
1.Removethecontrolpanelfromtherightconsole.
2.DisconnectthePTOswitchfromthewireharness.
3.WiththeswitchintheONposition(buttonpulledOUT).
g336409
Figure116
4.Usingadigitalmulti-metersettotheOHMorContinuitysetting,verifythe
following:
•Pin2and5shouldhavecontinuity(closed)
•Pin1and4shouldhavecontinuity(closed)
•Pin1and7shouldNOThavecontinuity(open)
•Pin2and8shouldNOThavecontinuity(open)
5.WiththeswitchintheOFFposition(buttonpushedIN):
•Pin1and7shouldhavecontinuity(closed)
•Pin2and8shouldhavecontinuity(closed)
•Pin1and4shouldNOThavecontinuity(open)
TITAN®MaxServiceManual
Page8–9
ElectricalSystem:ServiceandRepairs
3442-428RevA