Figure115
Note:TheenginewillnotcrankoverwhenthePTOswitchisintheONposition.
AllswitchesaresuppliedinparallelandfeedintotheHourMeter.
PTOSwitchTest
1.Removethecontrolpanelfromtherightconsole.
2.DisconnectthePTOswitchfromthewireharness.
3.WiththeswitchintheONposition(buttonpulledOUT).
g336409
Figure116
4.Usingadigitalmulti-metersettotheOHMorContinuitysetting,verifythe
following:
Pin2and5shouldhavecontinuity(closed)
Pin1and4shouldhavecontinuity(closed)
Pin1and7shouldNOThavecontinuity(open)
Pin2and8shouldNOThavecontinuity(open)
5.WiththeswitchintheOFFposition(buttonpushedIN):
Pin1and7shouldhavecontinuity(closed)
Pin2and8shouldhavecontinuity(closed)
Pin1and4shouldNOThavecontinuity(open)