9.Applyslightrearwardpressureonthe
motion-controllever,turntheheadofthe
adjustmentboltintheappropriatedirectionuntil
thecontrolleveriscenteredintheNEUTRAL-LOCK
position(Figure97).
Note:Keepingrearwardpressureonthelever
keepsthepinattheendoftheslotandallow
theadjustmentbolttomovethelevertothe
appropriateposition.
10.Tightenthenutandjamnut(Figure97).
11.Repeatfortheoppositesideofthemachine.
g001155
Figure97
1.Height-of-cutlever
5.Adjustmentbolt
2.Nutagainstyoke
6.Yoke
3.Jamnut
7.Spring
4.Clevispininslot
HydraulicSystem
Maintenance
HydraulicSystemSafety
•Seekimmediatemedicalattentionifuidisinjected
intoskin.Injecteduidmustbesurgicallyremoved
withinafewhoursbyadoctor.
•Ensurethatallhydraulic-uidhosesandlinesare
ingoodconditionandallhydraulicconnections
andttingsaretightbeforeapplyingpressureto
thehydraulicsystem.
•Keepyourbodyandhandsawayfrompinhole
leaksornozzlesthatejecthigh-pressurehydraulic
uid.
•Usecardboardorpapertondhydraulicleaks.
•Safelyrelieveallpressureinthehydraulicsystem
beforeperforminganyworkonthehydraulic
system.
ServicingtheHydraulic
System
Hydraulic-FluidSpecications
Hydraulic-FluidType:Toro
®
HYPR-OIL
™
500
hydraulicuidorMobil
®
115W-50uid
Important:Usethespecieduid.Otheruids
couldcausesystemdamage.
Hydraulic-SystemFluidCapacity:3.9L(132oz)
CheckingtheHydraulic-Fluid
Level
ServiceInterval:Aftertherst8hours
Every25hours
Note:Youcancheckthehydraulicuidwhenthe
uidiswarmoritiscold.Thebafeinsidethetank
has2levelsdependingiftheuidiswarmorcold.
1.Parkthemachineonalevelsurface,disengage
theblade-controlswitch,andengagetheparking
brake.
2.Shutofftheengine,removethekey,andwait
forallmovingpartstostopbeforeleavingthe
operatingposition.
3.Cleantheareaaroundthellerneckofthe
hydraulictank(Figure98).
4.Removethecapfromthellerneckandlook
insidetocheckifthereisuidinthereservoir
(Figure98).
66