EasyManua.ls Logo

Toshiba 3000 PROFIBUS - Page 26

Toshiba 3000 PROFIBUS
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
model 3000 PROFIBUS Module Users Manual
Chapter 3 Specifications
3
PF311/PF312 module specification
Table 3-2 PF311/PF312 module specification
Item
Description
PF311 PF312
Connected device Integrated controller model 3000
Connection bus G3 I/O bus
Number of connectable devices Up to 8 (total of PF311 and PF312)
Service Process data (cyclic data)
I/O, Input 512 bytes, output
512 bytes
RAS function by custom
procedure (mailbox)
Process data (cyclic data)
I/O, Input 244 bytesOutput
244 bytes
Access method from controller Batch I/O or direct I/O
Parameter setup method Dedicated configurator Setup switch and custom
configurator
Current consumption 0.9 A 0.7 A
Operating ambient temperature 0 to 55°C (must be fan cooled above 45°C)
External dimensions G3 I/O, occupies 1 slot
Specification Profibus Class 1 Master(EN50170)
RAS function Module status
Healthy counter
PROFIBUS-DP status

Related product manuals