1 TROUBLESHOOTING FOR THE HARDWARE
22 Clearing a Paper Misfeed
Paper misfeed in the automatic duplexing unit
Be careful not to let your fingers be caught between the equipment and the duplexing unit or automatic duplexing
unit.
This could injure you.
4
Lower the transfer unit carefully and then close the automatic duplexing unit.
3
Place paper in the bypass tray again and then move
the green paper holding lever toward the inside.
If a sheet of paper is stained, folded or torn, replace it with a new one.
2
1
1
Open the automatic duplexing unit on the right.
2
Remove paper misfed on the paper transport path
above the fuser unit. (Only for e-STUDIO356/456)
3
While holding the green lever to lift up the transfer
unit, remove the misfed paper.
2
1