EasyManua.ls Logo

Toshiba e-STUDIO 356 - Paper Misfeed in the Fuser Unit

Toshiba e-STUDIO 356
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 TROUBLESHOOTING FOR THE HARDWARE
24 Clearing a Paper Misfeed
Paper misfeed in the fuser unit
Be careful not to let your fingers be caught between the equipment and the duplexing unit or automatic
duplexing unit.
This could injure you.
Do not touch the fuser unit or the metal portion around it.
Since they are very hot, you could be burned or the shock could cause you to get your hand injured in the machine.
e-STUDIO256/356/456/506
1
Open the automatic duplexing unit on the right.
2
Press down the two green fuser pressure release
levers until they stop.
The fuser pressure release levers will automatically return to their
original position when the automatic duplexing unit is closed.
3
Open the transport guide holding the green knob and
then release the misfed paper. Pull the misfed paper
up or down as shown in the illustrations depending
on the position of the paper.
Pulling it up
Pulling it down
2
1

Table of Contents

Other manuals for Toshiba e-STUDIO 356

Related product manuals