June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 87
3
3.12.3 Adjusting the overlap of the sensor flag
If the overlap between the sensor and the flag is wrong for some reason, perform the following adjust-
ment.
<Procedure>
(1) Remove the processing tray unit.
(2) Loosen the mounting screw of the front/rear
jogging plate adjusting plate; then, move the
adjusting plate to the left and the right.
Fig.3-116
(3) Tighten the screw so that the overlap
between the flag of the front/rear jogging
rack plate and the sensor is 1.5 mm to 2.0
mm.
Fig.3-117
Jogging plate
adjusting plate
Jogging plate
adjusting plate
Screw
Screw
Adjusting
plate
Adjusting
plate