June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 53
3
3.10 Adjustment of the RADF (MR-3016)
3.10.1 Adjustment of RADF position
It is mainly performed at the installation. It is also required when the RADF is dislocated for some rea-
son such as moving the equipment.
Remove the platen sheet during adjustment.
<Procedure>
(1) Open the RADF and then attach 2 position-
ing pins to the equipment.
(The positioning pins have been attached at
the rear of the right-hand hinge of the RADF.)
Fig.3-50
(2) Close the RADF to check that the positioning
pins fit smoothly into the holes on the RADF.
If they do not, adjust them according to the
following procedure.
Fig.3-51
(3) Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
Fig.3-52
Positioning pin
1 turn
Half turn