e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 88
3.12.4 Adjusting the tension of the stack processing motor belt
<Procedure>
(1) Remove the right inner cover and the rear cover.
(2) Remove the 2 mounting screws, and detach
the grip unit.
Fig.3-118
(3) Loosen the screw on the tension arm plate.
(The tension arm plate will be pulled under
tension by the tension spring.)
Fig.3-119
(4) Move the returning roller shaft to its lower
limit (the slack of a belt is lightly taken); then,
tighten the screw on the tension arm plate.
Fig.3-120
Screw
Grip unit
Screw
Screw
Tension arm
plate
Screw
Tension arm
plate
Returning
roller shaft