June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 9
2
CDC0 Finisher related
service call
Punch power failure abnormality: 24 V is not applied to
the punch controller board.
[MJ-1025 (when MJ-6005 is installed)]
P. 5-74
CDD0 Folding position sensor abnormality: Automatic adjust-
ment of the folding position sensor can not be performed
properly. [MJ-1025]
P. 5-74
CDE0 Paddle motor abnormality: The paddle motor does not
rotate properly. [MJ-1025]
P. 5-75
CDF0 Offset tray related
service call
Initialization error of the offset tray: The home position of
the separator cannot be detected when the power is
turned ON.
P. 5-76
CE00 Finisher related
service call
Communication error between finisher unit and puncher
unit: Communication error between the finisher controller
PC board and punch controller PC board.
[MJ-1025 (when MJ-6005 is installed)]
P. 5-75
CF60 Other service call Toner for recycle transport area lock P. 5-76
F070 Communication
related service call
Communication error between System-CPU and Engine-
CPU
P. 5-58
F090 Other service call SRAM abnormality on the SYS board P. 5-76
F091 NVRAM abnormality on the SYS board P. 5-77
F092 SRAM and NVRAM abnormality on the SYS board P. 5-77
F100 HDD format error: HDD cannot be initialized normally. P. 5-77
F101 HDD unmounted: Connection of HDD cannot be
detected.
P. 5-77
F102 HDD start error: HDD cannot become ‘Ready’ state. P. 5-77
F103 HDD transfer time-out: Reading/writing cannot be per-
formed in the specified period of time.
P. 5-77
F104 HDD data error: Abnormality is detected in the data of
HDD.
P. 5-77
F105 HDD other error P. 5-77
F106 Point and Print partition damage P. 5-78
F107 /SHR partition damage P. 5-78
F108 /SHA partition damage P. 5-78
F110 Communication
related service call
Communication error between System-CPU and Scan-
ner-CPU
P. 5-58
F111 Scanner response abnormality P. 5-58
F120 Other service call Database abnormality: Database is not operating nor-
mally.
P. 5-78
F130 Invaid MAC address P. 5-78
F200 Data overwrite kit (GP-1050/1060) is taken off P. 5-78
Error code Classification Contents Troubleshooting