June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 TROUBLESHOOTING
5 - 23
5
[E410] Front cover opened during printing
Is the front cover open?
#
YES Close the cover.
NO
Is the front cover opening/closing switch working?
(Perform the input check in the test mode: 03-[FAX]ON/[2]/[D])
l
l
l
l
l
l
l
l
l
#
NO 1) Check if the connector of the front cover opening/closing switch is
disconnected.
2) Check if the connector CN303 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
5) Replace the front cover opening/closing switch.
6) Replace the LGC board.
YES
Is the voltage of 24V being supplied from the power supply unit?
(Perform the input check in the test mode: 03-[FAX] ON/[1]/[C])
l
l
l
l
l
l
l
#
NO 1) Check if the connector for 24 V power supply is disconnected.
2) Check if the connector CN303 on the LGC board is disconnected.
3) Check if the connector pins are disconnected and the harnesses are
open circuited.
4) Check if the conductor pattern on the LGC board is short circuited or
open circuited.
5) Replace the LGC board.
YES
Replace the LGC board.