June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 47
2
306 Scanner Image location adjustment
of primary scanning direc-
tion
(scanner section)
ALL 156
<0-255>
SYS When the value
increases by “1”, the
image shifts by approx.
0.0846 mm toward the
front side of the paper.
1
308 Scanner Distortion mode ALL - - Moves carriages to the
adjusting position.
(Chap. 3.2.4)
6
340 Scanner Reproduction ratio adjust-
ment of secondary scan-
ning direction
(scanner section)
ALL 129
<0-255>
SYS When the value
increases by “1”, the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.223%.
1
354 RADF Adjustment of
RADF paper
alignment
for single -
sided orig-
inal
ALL 10
<0-20>
SYS When the value
increases by “1”, the
aligning amount
increases by approx.
0.5 mm.
1
355 for double
sided orig-
inal
ALL 10
<0-20>
SYS 1
356 RADF Automatic adjustment of
RADF sensor and
EEPROM initialization
ALL - SYS Performs the adjustment
and initialization when
the RADF board or
RADF sensor is
replaced.
6
357 RADF Fine adjustment of RADF
transport speed
ALL 50
<0-100>
SYS When the value
increases by “1”, the
reproduction ratio of the
secondary scanning
direction when using the
RADF increases by
approx. 0.1%.
1
358 RADF RADF sideways deviation
adjustment
ALL 128
<0-255>
SYS When the value
increases by “1”, the
image of original fed
from the RADF shifts
toward the rear side of
paper by approx.
0.0846 mm.
1
359 Scanner Carriage position adjust-
ment during scanning from
RADF
ALL 128
<0-255>
SYS When the value
increases by “1”, the car-
riage position when
using the RADF shifts by
approx. 0.1 mm toward
the original feeding side.
1
365 RADF RADF lead-
ing edge posi-
tion
adjustment
for single -
sided orig-
inal
ALL 50
<0-100>
SYS When the value
increases by “1”, the
copied image of original
fed from the RADF shifts
toward the trailing edge
of paper by approx.
0.1 mm.
1
366 for double
sided orig-
inal
ALL 50
<0-100>
SYS 1