ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 76
593 Image Gamma data
slope adjust-
ment
Text/Photo PPC 0
<0-99>
SYS One’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope of
Gamma curve (The
larger the value is, the
larger the slope
becomes.)
Ten’s place:
0: Equivalent to the set
value 5
1 to 9: Select the slope of
low density (The smaller
the value is, the darker
the background
becomes.)
00: Use default value
1
594 Image Photo PPC 0
<0-99>
SYS 1
595 Image Text PPC 0
<0-99>
SYS 1
596-0 Image Gamma bal-
ance adjust-
ment
(PS/Photo)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density in
the target area becomes
higher.
4
596-1 Image Medium
density
PRT 128
<0-255>
SYS 4
596-2 Image High
density
PRT 128
<0-255>
SYS 4
597-0 Image Gamma bal-
ance adjust-
ment
(PS/Text)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density in
the target area becomes
higher.
4
597-1 Image Medium
density
PRT 128
<0-255>
SYS 4
597-2 Image High
density
PRT 128
<0-255>
SYS 4
598-0 Image Gamma bal-
ance adjust-
ment
(PCL/Photo)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density in
the target area becomes
higher.
4
598-1 Image Medium
density
PRT 128
<0-255>
SYS 4
598-2 Image High
density
PRT 128
<0-255>
SYS 4
599-0 Image Adjustment of
gamma bal-
ance
(PCL/Detail)
Low
density
PRT 128
<0-255>
SYS When the value
increases, the density in
the target area becomes
higher.
4
599-1 Image Medium
density
PRT 128
<0-255>
SYS 4
599-2 Image High
density
PRT 128
<0-255>
SYS 4
Adjustment mode (05) <e-STUDIO202L/203L/232/233/282/283>
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
07/11