EasyManua.ls Logo

Toshiba e-STUDIO230 - Page 282

Toshiba e-STUDIO230
708 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO200L/202L/230/232/280/282 ERROR CODE AND SELF-DIAGNOSTIC MODE June 2004 © TOSHIBA TEC
2 - 246
4) Relation between pixel count and toner consumption
The user’s printing out the image with large coverage or high density may cause the large value of
pixel count. And the setting that toner consumption becomes high in the original mode or density
setting may cause it as well.
In this case, the replacement cycle of toner cartridge is faster than the standard number of output
pages. Therefore, this trend needs to be grasped for the service.
The relation between pixel count and number of output pages per cartridge is as follows:
Fig. 2-11 Pixel count and number of output pages per cartridge
6% 12%
60%
X
X/2
X/10
Standard number of output pages
Number of output pages per cartridge (page)
Pixel count (%)
05/05