e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 2
(4) After about two minutes, the value B automatically starts changing.
Fig.3-3
(5) After a short time, the value B becomes stable and the display changes as follows.
Fig.3-4
(6) Check if the value B is within the range of 235 to 245 (the output voltage range of the auto-toner
sensor is 2.35 V to 2.45 V).
(7) If the value B is not within the range of 235 to 245, press the Up or Down button to adjust the
value manually.
Note: Note:
The relation between the button and the values A and B is as follows.
(8) Press the [ENTER] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
Fig.3-5
(9) Turn the power OFF.
(10) Install the toner cartridge.
Button to be pressed Value A Value B
Up Increased Increased
Down Decreased Decreased
230%
128
200
TEST MODE WAIT
A3
128
240%
128
200
ADJUSTMENT MODE
A3
150
A
B
[ENTER]
or
[INTERRUPT]
100%
TEST MODE
A3
A

Table of Contents