June 2004 © TOSHIBA TEC e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT
3 - 11
3
Fig.3-8 Grid pattern
<Procedure>
Perform 08-477 and check the value.
When the value is 0.
[0] [5] [Power ON] # [1] ([3](05-445, 498) for duplexing) # [FAX]
A: 05-401 (Lower drawer, A3/LD)
# 200±0.5 mm (0.125 mm/step)
B: 05-411 (Lower drawer, A3/LD)
# 52±0.5 mm (0.05 mm/step)
# Key in the same value for 05-410.
C: 05-421 (Lower drawer, A3/LD)
# 200±0.5 mm (0.125 mm/step)
D: 05-441 (Lower drawer, A3/LD), 440 (Upper drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
# 52±0.5 mm(0.4 mm/step)
E: 05-498-0 (Lower drawer, A3/LD),
498-1 (Upper drawer, A4/LT)
# 52±0.5 mm (0.05 mm/step)
A
21
6
1
B, E
D
6
30 2
C
10
Feeding direction
04/09