e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 16
[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. # (Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) Press [FAX] to make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment
(Refer to *).
*Perform 08-477 and check the value.
If the value is 0, use the lower drawer.
If the value is 1, use the upper drawer.
(4) Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(5) Check if the distance C is within the range of 200±0.5 mm.
(6) If not, use the following procedure to change values and repeat steps (3) to (5) above.
(Adjustment Mode) # (Key in the code [340]) # [START]
# (Key in a value (acceptable values: 0 to 255))
# Press the [ENTER] or the [INTERRUPT] button (stored in memory).
# (“100% A” is displayed.)
*The smaller the adjustment value is, the lower the reproduction ratio becomes (0.45 mm/step).
Fig.3-14
200 250 300 350 40050 100 150
C
Feeding direction
Copied image of the ruler
04/09