e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 34
[A] Installation of the high-voltage transformer jig
(1) Open the bypass tray, ADU and transfer
cover.
(2) Open the front cover and take off the toner
cartridge.
(3) Disconnect 1 connector. Loosen 2 screws
and pull out the process unit.
Note: Note:
Be careful not to let the connector and the
harness be caught when installing the pro-
cess unit after adjustment.
Fig.3-19
(4) Install the high-voltage transformer jig and fix
it with 2 screws.
Note: Note:
Be careful not to let the connector and the
harness be caught.
Fig.3-20
(5) Fix the green cable of the high-voltage trans-
former jig to the frame of the equipment.
Fig.3-21
Process unit Connector
High-voltage transformer jig
Screw
Green cable
04/09