e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 36
[B] Connection for developer bias adjustment
Fig.3-23
[C] Connection for main charger adjustment
Fig.3-24
Front cover opening/closing switch
Ground to the
machine frame
(
green cable
)
(
-
)
terminal:
Connect with the white cable
(
+
)
terminal:
Connect with the black cable
Front cover opening/closing switch
Ground to the
machine frame
(
green cable
)
(
-
)
terminal:
Connect with the white cable
(
+
)
terminal:
Connect with the
red cable
(
thick line
)