e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT June 2004 © TOSHIBA TEC
3 - 60
(2) Step 2
Case C:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw counterclockwise.
Case D:
Loosen the fixing screw and hand screw of the right side hinge and then turn the adjustment
screw clockwise.
Note: Note:
When adjusting, refer to the hinge position (scribed line) and be sure not to move it from the
hinge position ±0.5 mm or further. Otherwise, image failures such as a jitter may occur.
(3) Step 3
Case E:
Adjust the reverse aligning adjustment position to the rear side “-” of the original (! P.3-63
"3.10.6 Adjustment of aligning at reversing").
Case F:
Adjust the reverse aligning adjustment position to the rear side “+” of the original (! P.3-63
"3.10.6 Adjustment of aligning at reversing").
Fig.3-68
Fig.3-66 Fig.3-67
C D
Paper
Original
Fixing screw
Adjustment screw
Hand screw
RADF
Front side
E F
Paper