(E) Replace the toner cartridge ( )
(F) Developer unit not installed properly
(G) Call for service
Error code is displayed instead of the set number by pressing the [CLEAR] button and [8] button
simultaneously when the “Call for service” is blinking.
Refer to the error code table in the Service Handbook.
• The 1st/2nd transport sensor and each sensors of PFP/LCF are not turned ON in a fixed period of
time after the feed clutch is turned ON
Paper jam (E220, E310, E320, E340–E360, E3D0 and E3E0: Error code differs depending on the
paper source.) Refer to the error code table in the Service Handbook.
• Toner density becomes low
Auto-toner sensor detects the absence of the toner
Control circuit “Install new toner cartridge” displayed: the copying operation disabled
Solution: Open the front cover and replace the toner cartridge with a new one.
Toner is supplied copying operation enabled.
• Disconnection of the connectors of the developer unit
“Developer unit not installed” is displayed.