EasyManua.ls Logo

Toshiba e-STUDIO350 - Setting Range Correction

Toshiba e-STUDIO350
764 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO350/352/353/450/452/453 © 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 28
3.5.3 Setting range correction
The values of the background peak / text peak in the range correction can be switched to “varied” or
“fixed” in the following codes.
If they are fixed, the range correction is performed with standard values.
The values of the background peak affect the reproduction of the background density and the values of
the text peak affect that of the text density.
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of P. 3-26 "3.5.1 Density adjustment".
3.5.4 Setting range correction (Adjustment of background peak)
The levels of the background peak for the range correction can be set at the following codes.
< Adjustment Mode (05) >
<Procedure>
Procedure is same as that of P. 3-26 "3.5.1 Density adjustment".
Original mode
Item to be adjusted Remarks
Text/Photo Photo Text
825 827 826 Range correction for
original manually set
on the original glass
The following are the default values set for each
original mode.
Text/Photo: 12, Photo: 12, Text: 12
Each digit stands for:
One’s place: Automatic density mode
Ten’s place: Manual density mode
The setting conditions possible are as follows:
Background peak Text peak
1: fixed fixed
2: varied fixed
3: fixed varied
4: varied varied
830 832 831 Range correction for
original set on the
RADF
Original mode
Item to be adjusted Remarks
Text/Photo Photo Text
835 837 836 Background peak for
range correction
When the value increases, the background (low
density area) of the image is not output.
Acceptable values: 0 to 255
(Default: text/photo: 48, photo: 40, text: 48)

Table of Contents

Other manuals for Toshiba e-STUDIO350

Related product manuals