6
If the updating of the NIC firmware is still failed, check the prescription corresponding to the error
message. After confirming and clearing the problem, restart updating from the beginning.
Note: Note:
If the updating of the NIC firmware is not completed properly, wait 5 minutes or more from the
beginning of the updating before turning OFF the power, and then restart updating from the
beginning. If you turn OFF the power within 5 minutes, HDD may be destroyed.
(16) Turn OFF the power of the equipment.
(17) Perform the initialization of the updating data (NVRAM updating).
a. Turn ON the power while [0] button and [8] button are pressed simultaneously.
b. Key in “947”, and then press the [START] button.
c. Press the [INITIALIZE] button.
NIC Error Message Error Contents Prescription
NIC UPDATE FAILED 1 NIC initialization time-out The IP address may not be assigned cor-
rectly.
• Is the IP address assigned correctly?
• Does the IP address conflict with the
other system?
If the error still occurs, replace the NIC
board because it may be destroyed.
NIC UPDATE FAILED 2 ATA driver initialization error The HDD cable may be disconnected.
• Is the HDD cable connected correctly?
If the HDD cable is connected correctly,
replace the SYS board because it may be
destroyed.
NIC UPDATE FAILED 3 HDD partition mount error Replace the HDD because it may be
destroyed.
NIC UPDATE FAILED 4 NIC setting information
backup error
Replace the HDD because it may be
destroyed.
NIC UPDATE FAILED 5 NIC firmware transfer error Replace the NIC board because it may be
destroyed.
NIC UPDATE FAILED 6 NIC firmware writing error Replace the NIC board because it may be
destroyed.
NIC UPDATE FAILED 7 NIC status time-out Replace the NIC board because it may be
destroyed.
04/10